YSI Pro Plus Multiparameter |
|
Page Content
YSI Pro Plus Multiparameter
Overview
YSI Pro Plus Multiparameter
Smartest
YSI Pro Plus Multiparameter
Versatile
YSI Pro Plus Multiparameter
Data Manager
YSI Pro Plus Multiparameter
Features
YSI Pro Plus Multiparameter
Instrument Specifications
YSI Pro Plus Multiparameter
System Specifications
YSI Pro Plus Multiparameter
Ordering Guide
YSI Pro Plus Multiparameter
Overview
The YSI Pro Plus Multiparameter
handheld multiparameter meter provides extreme flexibility for the measurement of a variety of combinations:
- dissolved oxygen measurement
- conductivity measurement
- specific conductance measurement
- salinity measurement
- resistivity,
- total dissolved solids (TDS),
- pH,
- ORP,
- pH/ORP combination,
- ammonium (ammonia),
- nitrate,
- chloride,
- temperature, also
- a very powerful lab instrument for BODs, pH and ORP.
Back to Page Content
YSI Pro Plus Multiparameter
Smartest
The YSI
Meter provides numerous benefits from the following features; 5,000 data-set memory, password protection, backlit display and keypad, graphic display with detailed Help functionality, re-cal prompts, user defined fields, detailed GLP, auto stable, Hold All Readings function, Data Manager software for the desktop, USB connection, auto-buffer recognition, and flexible folders and site lists for logging data.
Back to Page Content
YSI Pro Plus Multiparameter
Versatile
Connect any Professional Series cable (excludes ODO cables) and probe option to the
YSI Meter and use the convenient cable management kit to keep everything simple and organized. Cable options range from 1-, 4-, 10-, 20-, and 30-meter choices (up to 100-meters on DO only cables). Use lab or field probes and switch between the two quickly. The Pro Plus makes an ideal lab BOD instrument with the proven self-stirring BOD probe. A convenient handstrap can be used on either side of the instrument. A complete family of accessories also increases the versatility of the Pro
Plus YSI Meter. Choose among accessories for the YSI Meter including carrying cases, flow cells, cable weight, belt clip, tripod, and c-clamp.
Back to Page Content
YSI Pro Plus Multiparameter
Data Manager
Data management can become a daunting task over time but with the Data Manager software this task is much simpler and efficient. Download
data such as salinity measurement, configure instruments, and conduct real-time studies easily with Data Manager software. View data graphically or in tabular form and export data as needed to other programs. Data Manager software is a very powerful tool. So powerful in fact, that we give it to you at no charge when purchasing a Pro
Plus YSI Meter. After all, it's all about the data!
When purchasing the Pro Plus
YSI Meter you will receive the instrument, manual, batteries, communications saddle, USB cable, and Data Manager software. Cables and probes are ordered separately.
Back to Page Content
YSI Pro Plus Multiparameter
Features
- IP-67 with 3-year warranty
- 5,000 data-set memory
- Interval or single event logging
- Free - Data Manager software
- Measure a variety of parameter combinations
Back to Page Content
YSI Pro Plus Multiparameter
Instrument Specifications
- YSI Pro Plus Multiparameter
Auto Stable : User-defined auto-stable function holds stable readings on display when criteria is met
- YSI Pro Plus Multiparameter
Barometer Built-in barometer
- YSI Pro Plus Multiparameter
Buffer Recognition : Auto buffer recognition for US and NIST buffers
- YSI Pro Plus Multiparameter
Certifications: RoHS, CE, WEEE, C-Tick, VCCI, FCC, IP-67, 1-meter drop test, Assembled in USA
- YSI Pro Plus Multiparameter
Connectivity: USB 2.0; ProComm II communications saddle and USB cable included; user-upgradeable software via USB and website
- YSI Pro Plus Multiparameter
Connector: MS (military spec) waterproof with bayonet lock
- YSI Pro Plus Multiparameter
Data Management: Data Manager desktop software included; 100 user-defined folders and site names
- YSI Pro Plus Multiparameter
Data Memory: 5,000 data sets (data, date, time, user-defined info); 100 GLP files
- YSI Pro Plus Multiparameter
Dimensions: 8.3 cm width x 21.6 cm length x 5.6 cm depth (3.25 in x 8.5 in x 2.21 in)
- YSI Pro Plus Multiparameter
Display: Graphic display with detailed Help; backlit display AND keypad
- YSI Pro Plus Multiparameter
DO Sensors : Polarographic or galvanic field sensors; self-stirring polarographic BOD sensor for the lab
- YSI Pro Plus Multiparameter
Field Cables: Standard lengths of 1, 4, 10, 20, or 30 meters - up to 100 meters on DO only cables; 4- through 30-meter cables include a cable management kit
- YSI Pro Plus Multiparameter
Flow Cell: Single, dual and multiparameter Quatro cable all flow cell compatible
- YSI Pro Plus Multiparameter
GLP Compliance: Yes; detailed GLP information is stored and is available to view, download or print
- YSI Pro Plus Multiparameter
Lab Cables: BOD sensor includes 2-meter cable; 1 or 4 meters on lab pH, ORP and pH/ORP cables
- YSI Pro Plus Multiparameter
Languages : English, Spanish, German, French, Italian, Norwegian, Portuguese, Japanese, Chinese (Simplified & Traditional)
- YSI Pro Plus Multiparameter
Logging Modes: Single or Continuous
- YSI Pro Plus Multiparameter
Operating Temperature: -10 to 60°C
- YSI Pro Plus Multiparameter
Power: 2 alkaline C-cells provide 80 continuous hours at ambient temperature without backlight; ProComm II saddle provides USB power or optional wall power, cigarette lighter, and universal cell phone charger options
- YSI Pro Plus Multiparameter
Storage Temperature: -20 to 70°C
- YSI Pro Plus Multiparameter
User ID: Optional user ID for data security
- YSI Pro Plus Multiparameter
Warranty: 3-year instrument; 2-year field cables
- YSI Pro Plus Multiparameter
Waterproof: IP-67 (even with the battery cover off); floats
- YSI Pro Plus Multiparameter
Weight with Batteries: 475 grams (1.05 lbs)
Back to Page Content
YSI Pro Plus Multiparameter
System Specifications
Professional Plus System Specifications (Cables & Sensors)
|
Sensor Type |
Range |
Accuracy |
Resolution |
Units |
Calibration |
Dissolved Oxygen Measurement (%)
(temp comp range -5 to 45°C) |
Polarographic or Galvanic |
0 to 500% |
0 to 200%
(± 2% of reading or 2% air saturation, whichever is greater)
200% – 500% (± 6% of reading) |
1% or 0.1% air saturation
(user selectable) |
%
|
1 or 2-points with zero |
Dissolved Oxygen Measurement (mg/L)
(temp comp range -5 to 45°C) |
Polarographic or Galvanic |
0 to 50 mg/L |
0 to 20 mg/L
(± 2% of reading or 0.2 mg/L, whichever is greater)
20 – 50 mg/L (± 6% of reading) |
0.1 or 0.01 mg/L (user selectable); 0.1% air saturation
|
mg/L, ppm
|
1 or 2-points with zero |
Temperature
(Field rugged cables) |
|
-5 to 70°C |
±0.2°C (±0.3°C cables over 45-meters)
|
0.1°C |
°C, °F, K |
|
Temperature
(Lab-grade)* |
|
0 to 40°C |
±0.35°C |
0.1°C |
°C, °F, K |
|
Conductivity Measurement** |
Four electrode cell |
0 to 200 mS/cm
(auto range)
|
±0.5% of reading or 0.001 mS/cm, whichever is greater (4-m
cable) ±1% of reading or 0.001 mS/cm, whichever
is greater (20-m cable) |
0.001 mS/cm to 0.1 mS/cm (range dependent) |
µS, mS
|
1 point |
Salinity Measurement |
Calculated from conductivity measurement and temperature |
0 to 70 ppt |
±1.0% of reading or 0.1 ppt, whichever is greater |
0.01 ppt |
ppt, PSU
|
1 point
|
pH Measurement |
Glass Combination Electrode |
0 to 14 units |
±0.2 units |
0.01 units |
mV, pH units
|
1, 2, 3, 4, 5, or 6 point (user selectable);
US, NIST or Custom Buffers |
ORP |
Platinum button |
--1999 to +1999 mV |
±20 mV in redox standards |
0.1 mV
|
mV |
1 point |
Ammonium***
(ammonia with pH measurement sensor)
|
Ion Selective Electrode
|
0 to 200 mg/L-N, 0 to 30°C |
±10% of reading or 2 mg/L-N, whichever is greater |
0.01 mg/L |
mg/L-N, mV
|
1, 2, or 3 point
(user selectable)
|
Nitrate*** |
Ion Selective Electrode
|
0 to 200 mg/L-N, 0 to 30°C |
±10% of reading or 2 mg/L-N,
whichever is greater |
0.01 mg/L |
mg/L-N, mV
|
1, 2, or 3 point
(user selectable) |
Chloride***
|
Ion Selective Electrode
|
0 to 1000 mg/L, 0 to 40°C
|
±15% of reading or 5 mg/L, whichever is greater |
0.01 mg/L |
mg/L-Cl-, mV
|
1, 2, or 3 point
(user selectable) |
Total Dissolved Solids (TDS)
|
Calculated from conductivity measurement and temperature
|
0 to 100 g/L TDS constant range 0.30 to 1.00 (0.64 default) |
|
0.001, 0.01, 0.1g/L |
kg/L, g/L |
|
Barometer |
Piezoresistive |
375 to 825 mmHg |
±1.5 mmHg from 0 to 50°C |
0.1 mmHg
|
mmHg, inHg, mbar, psi, kPa, ATM |
1 point |
Instrument Only Specifications (at Ambient
Temperature) |
pH Measurement |
|
-2.60 to 16.60
|
±0.1 mV (0.01 pH units)
|
0.1 mV (0.01 pH units) |
|
|
ORP |
|
-1999 to +1999 mV
|
±0.5 mV
|
0.1 mV |
|
|
Conductivity Measurement |
|
0.0 to 200 mS/cm each range
|
±0.1% FS ±1 digit for µS/cm to 0.1 mS/cm (range dependent) |
0.0001 mS/cm or 0.1 |
|
|
Dissolved Oxygen Measurement |
|
0.00 to 90 mg/L; 0 to 550% |
±0.2% FS (550% air saturation) ±1 digit (with 1.25 PE
membrane at 10°C) |
0.01 mg/L; 0.1% air saturation |
|
|
Temperature |
|
-10 to 100.00°C |
±0.2% FS ±1 digit
|
0.1°C
|
°C, °F, K |
|
*Lab-grade cables include
605107, -108, -109, 605177, -178, -179
** Derived parameters can include resistivity, salinity
measurement, specifi
c conductance, and total dissolved solids
***ISE sensors for freshwater only; 17-meter maximum depth
|
Back to Page Content
YSI Pro Plus Multiparameter
Ordering Guide
Step 1: |
Order Instrument |
Item #
|
Description |
6050000 |
Instrument, includes Data Manager software, the ProComm II
communications saddle, and USB cable |
|
|
Step 2:
|
Order Cable(s)
All cables include temperature; cables 4- through 30-meters
include cable management kit; cables with conductivity include
sensor (no need to order conductivity measurement sensor) |
60510 |
1, 4, 10, 20 or 30 meter: ISE1/temp |
60520 |
1, 4, 10, 20, 30 or up to100 meters2: DO/temp |
60530 |
1, 4, 10, 20 or 30 meter: conductivity/temp |
6051010 |
1, 4, 10, 20 or 30 meter: ISE/ISE/temp |
6051020 |
1, 4, 10, 20 or 30 meter: ISE/DO/temp |
6051030 |
1, 4, 10, 20 or 30 meter: ISE/conductivity/temp |
6052030 |
1, 4, 10, 20 or 30 meter: DO/conductivity/temp |
605790 |
1, 4, 10, 20 or 30 meter: ISE/ISE/DO/conductivity/temp |
605107 |
1–meter single junction pH sensor & cable |
605177 |
4–meter single junction pH sensor & cable |
605108 |
1–meter single junction ORP sensor & cable |
605178 |
4–meter single junction ORP sensor & cable |
605109 |
1–meter single junction pH/ORP sensor & cable |
605179 |
4–meter single junction pH/ORP sensor & cable |
|
|
Step 3:
|
Order Sensor(s) |
605202 |
Galvanic DO |
605203 |
Polarographic DO |
605780 |
Self-stirring BOD (2-meter cable included) |
605101 |
pH (ISE) |
605102 |
ORP (ISE) |
605103 |
pH/ORP combination (ISE)3
|
605104 |
Ammonium (ISE) |
605105 |
Chloride (ISE) |
605106 |
Nitrate (ISE) |
1 ISEs include pH, ORP, Ammonium, Nitrate,
Chloride
2 Special order cables in 10-meter increments up to 100 meter
available
3 Not recommended on 6051010 or 605790 cables. Only pH
measurement would
appear. |
Back to Page Content
|
|
|
|