    Rugged TROLL 100 Data Logger

    Rugged TROLL 100 Features

    Benefits of the Rugged TROLL 100

    Rugged TROLL 100 Specifications

    In-Situ Rugged TROLL 100, 200, and Rugged BaroTROLL Comparision


Rugged TROLL 100 Data Logger

 

Overview

 

The Rugged TROLL 100 is In-Situ’s most economical option for measuring and logging water level, water pressure, and temperature. This non-vented (absolute) water level logger is ideal for flood-prone or high humidity environments, allowing you to periodically download data with the Rugged TROLL Docking Station. Plus, titanium construction gives you long-lasting performance in fresh or saline groundwater and surface-water environments

Back to Page Content


Rugged TROLL 100 Features

 

  • Non-vented (absolute) pressure measurements
  • Available in pressure ranges up to 250 ft (76 m).
  • 2.62 cm (1.03 in.) diameter
  • Suspension wire deployment
  • Titanium body with Delrin nose cone and backend
  • 10-year internal battery
  • Download data via Rugged TROLL Docking Station
  • NIST calibration report

Back to Page Content


Benefits of the Rugged TROLL 100

 

  • Minimize project costs – Economical water level logger is affordable on any budget, with titanium construction that outlasts coated stainless steel data loggers.
  • Zero maintenance – Water level logger requires no desiccant, and batteries last 10+ years.
  • Simplify setup and data retrieval – Easily program and download data with the Rugged TROLL Docking Station (sold separately).

Back to Page Content


Rugged TROLL 100 Specifications

 

Weight 1 lbs
Dimensions 5.68 x 1.03 in
Level/Depth/Pressure Sensor Accuracy @ 15° C ±0.05% Full Scale
Protocols Modbus/RS485, SDI-12
Memory 1.0 MB
Battery Type 3.6 V lithium
Battery Life 10 years
Diameter 2.62 cm (1.03 in.) OD
Warranty 2 Year
Level/Depth/Pressure Sensor Range 10 psia: 9 m (30 ft), 40 psia: 30 m (100 ft), 110 psia: 76 m (250 ft)

Back to Page Content


In-Situ Rugged TROLL 100, 200, and Rugged BaroTROLL Comparision

 

General Rugged TROLL 100 & 200 Rugged BaroTROLL
Temperature ranges1 Operational: 0-50° C (32-122° F) 
Storage: -40-80° C (-40-176° F) 
Calibrated: 0-50° C (32-122° F)
Operational: 0-50° C (32-122° F)
Storage: -40-80° C (-40-176° F)
Calibrated: 0-50° C (32-122° F)
Diameter 2.62 cm (1.03 in.) 2.62 cm (1.03 in.)
Length 14.43 cm (5.68 in.) 14.43 cm (5.68 in.)
Weight 170 g (0.37 lb) 170 g (0.37 lb)
Materials Titanium body; Delrin® nose cone, hanger, backend Titanium body; Delrin nose cone, hanger, backend
Output options Rugged TROLL 100: USB or RS232 via
docking station
Rugged TROLL 200: USB or RS232 via
docking station; Modbus/RS485 or
SDI-12 via Rugged TROLL 200 Cable
USB or RS232 via docking station;
Modbus/RS485 or SDI-12 via Rugged TROLL 200 Cable
Battery type & life2 3.6V lithium; 10 years or 2M readings 3.6V lithium; 10 years or 2M readings
External power Rugged TROLL 100: NA Rugged TROLL 200: 8-36 VDC 8-36 VDC
Memory
Data records
Data logs
2.0 MB
120,000 
Rugged TROLL 100: 1 log 
Rugged TROLL 200: 2 logs

2.0 MB 
120,000
2 logs

Fastest logging rate 1 per second 1 per minute
Fastest output rate Rugged TROLL 200 only Modbus & SDI-12: 1 per second Modbus & SDI-12: 1 per second
Log types Linear, Fast Linear, and Event Linear
Sensor Type/Material Piezoresistive; Ceramic Piezoresistive; Ceramic
Range 9 m (30 ft) (Burst: 18 m; 60 ft)
30 m (100 ft) (Burst: 40 m; 134 ft)
76 m (250 ft) (Burst: 112 m; 368 ft)
7 to 30 psi; 0.5 to 2 bar
Accuracy4 ±0.1% full scale (FS) typical
±0.3% FS max
±0.1% FS typical
±0.3% FS max
Resolution ±0.01% FS or better ±0.01% FS or better
Units of measure Pressure: psi, kPa, bar, mbar, mmHg
Level: in., ft, mm, cm, m
Pressure: psi, kPa, bar, mbar, mmHg, inHg
Temperature Sensor Silicon Silicon
Accuracy ±0.3° C ±0.3° C
Resolution 0.01° C or better 0.01° C or better
Units of measure Celsius or Fahrenheit Celsius or Fahrenheit
Warranty 2 years 2 years
Notes: 1 Temperature range for non-freezing liquids. 2 Typical battery life when used within the factorycalibrated temperature range. 3 1 data record = date/time plus 2 parameters logged for a total of 360,000 data points, no wrapping. 4 Across factory-calibrated pressure and temperature ranges. Delrin is a registered trademark of E.I. du Pont de Nemours & Co. Specifications are subject to change without notice.